Detail Specifications
Thread Pitch Diameters:
+0.4752/+0.4787 inches
Body Style:
Multipole-single actuator type
Bushing Length:
0.625 inches
Body Length:
2.000 inches
Center To Center Distance Between Terminals Parallel To Length:
1.530 inches
Center To Center Distance Between Terminals Parallel To Width:
0.750 inches
Nonturn Device Location:
At 12 oclock and at 3 oclock and at 9 oclock
Nonturn Device Radius:
0.656 inches
Nonturn Device Length:
0.130 inches
Nonturn Device Diameter:
Between 0.151 inches and 0.161 inches
Fragility Factor:
Moderately rugged
Mounting Surface To Terminal End Distance:
2.232 inches
Arc Quenching Method:
Magnetic blowout
Mounting Facility Type And Quantity:
1 threaded bushing w/panel seal
Storage Type:
General purpose warehouse
Special Handling Feature:
Magnetic
Thready Qty Per Inch (tpi):
32
Maximum Continuous Load Current Rating Per Pole:
3.0 amperes ac second location
Maximum Continuous Load Current Rating Per Pole:
3.0 amperes ac third location
Maximum Continuous Load Current Rating Per Pole:
6.0 amperes dc first location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac second location
Operating Voltage Type And Rating Per Pole In Volts:
250.0 ac third location
Operating Voltage Type And Rating Per Pole In Volts:
65.0 dc first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
2000.0 dc first location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
3500.0 ac second location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps:
3500.0 ac third location
Circuit Protection Type:
Overcurrent all locations
Trip Release Method:
Magnetic-hydraulic all locations
Trip Release Characteristic:
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent:
115.0 all locations
Main Contact Tripping Mechanism Type:
Trip free
Manual Actuator Type And Quantity:
1 toggle
Actuator Function:
Trip-reset
Actuator Position Designation:
At pole two
Internal Trip Release Configuration:
Series trip all locations
Thread Size:
0.500 inches
Trip Delay Time In Seconds Per Rated Continuous Current:
20.000 at 200 pct first location and 70.000 at 200 pct first location
Trip Delay Time In Seconds Per Rated Continuous Current:
10.000 at 200 pct second location and 70.000 at 200 pct second location
Trip Delay Time In Seconds Per Rated Continuous Current:
10.000 at 200 pct third location and 70.000 at 200 pct third location
Inclosure Protection Type For Which Designed:
Hermetically sealed and shock resistant and vibration resistant
Frequency In Hertz:
50.0 second location or 60.0 second location
Frequency In Hertz:
50.0 third location or 60.0 third location
Unpackaged Unit Weight:
9.000 ounces
Thread Series Designator:
Un
Terminal Type And Quantity:
6 tab w/screw
Item Name:
Breaker,circuit
Manufacturer Part Numbers
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC